This document provides a comprehensive reference of all supported devices monitored via Modbus, organised by device category. Each device entry lists the monitored parameters and their units.
All devices communicate over Modbus RTU or Modbus TCP. Each device profile defines the register addresses, data types, and scaling factors needed to read parameters from the device.
Meters
ABB
ABB A44
Basic energy meter profile.
Parameter
Unit
Active import energy
kWh
Active export energy
kWh
Active import power
kW
ABB A44 (Harmonics Only)
Extended harmonic analysis profile with THD and individual harmonics (2nd–16th) across all phases.
Parameter
Unit
L1-N THD
%
L1-N 2nd–16th Harmonic
%
L2-N THD
%
L2-N 2nd–16th Harmonic
%
L3-N THD
%
L3-N 2nd–16th Harmonic
%
L1-L2 THD
%
L1-L2 2nd–16th Harmonic
%
L3-L2 THD
%
L3-L2 2nd–16th Harmonic
%
L1-L3 THD
%
L1-L3 2nd–16th Harmonic
%
L1 Current THD
%
L1 2nd–16th Harmonic
%
L2 Current THD
%
L2 2nd–16th Harmonic
%
L3 Current THD
%
L3 2nd–16th Harmonic
%
N Current THD
%
N 2nd–16th Harmonic
%
160 parameters total — THD + 15 harmonic orders across 10 measurement points.
ABB M4M
Full 3-phase measurement profile.
Parameter
Unit
Active import energy
kWh
Active export energy
kWh
Voltage L1-N, L2-N, L3-N
V
Voltage L1-L2, L2-L3, L3-L1
V
Current L1, L2, L3
A
Active import power
kW
Reactive import power
kvar
Apparent import power
kVA
Grid Frequency
Hz
Power factor
—
ABB Meter With Export
Same parameters as ABB M4M (16 parameters).
ABB Steel Meter
Minimal meter.
Parameter
Unit
Active import energy
kWh
Active import power
kW
ABB Meter Export Limit
Single parameter used for export limitation feedback.
Parameter
Unit
Active import power
W
Acuvim / Accuenergy
Acuvim Accuenergy II
Full measurement profile.
Parameter
Unit
Basic Parameter Mode
—
Active import power (Old)
kW
Active import energy
kWh
Active export energy
kWh
Grid Frequency
Hz
Voltage L1-L2, L2-L3, L3-L1
V
Current L1, L2, L3, N
A
Active import power L1, L2, L3
kW
Active import power
kW
Reactive import power
kW
Apparent import power
kW
Power factor
—
Acuvim Accuenergy II — CT Ratio Variants
Multiple profiles exist for various CT ratios used with 11kV/110V transformers. All share the same 7 parameters:
Temperatures (Control Board, DC Modules, Inverter Modules)
°C
Operational Mode State
Enum
Event Codes (DC-AC, DC-DC, Comm MCU)
Enum
Alarm Code
Enum
SMA
SMA 1 Phase Inverter
Parameter
Unit
Yield
kWh
Active / Apparent / Reactive power
kW / VA / kvar
Grid Frequency
Hz
Voltage L1-N
V
Current L1
A
DC Power, Voltage, Current
kW / V / A
Operating state / Recommended Action
Enum
SMA 3 Phase Inverter
Parameter
Unit
Operating state / Recommended Action
Enum
Yield
kWh
DC Current, Voltage, Power
A / V / kW
Active power
kW
Voltage (L-N and L-L, all phases)
V
Current L1, L2, L3
A
Grid Frequency
Hz
Reactive / Apparent power
kvar / VA
SMA STP60/SHP75/STPS60
17 parameters — AC/DC measurements plus operating state.
SMA STP 50 PKG 1.03
Extended profile (33 parameters) with 6 DC inputs and power factor.
SMA STP nn000TL-US-10
21 parameters with 2 DC inputs and power factor.
SMA STP110-60
47 parameters with 12 MPPT inputs and scale factors.
SMA Data Manager
System-level aggregation (29 parameters):
Parameter
Unit
Operating state
Enum
Accumulated PV inverter power
W
Total energy fed in
Wh
Current PV feed-in active power
W
Reactive power (all conductors)
VAr
Battery SOC
%
Power limitation (digital input)
%
Active / Reactive power at PCC
W / VAr
Battery charge / discharge (current & total)
W / Wh
Per-phase power at PCC (L1, L2, L3)
W
Per-phase reactive power at PCC
VAr
System voltages at PCC (L-L and L-N)
V
Grid frequency at PCC
Hz
System current at PCC (L1, L2, L3)
A
Solax
Solax PV Inverter
Parameter
Unit
DC Voltage 1, 2
V
Device Temperature
°C
Frequency
Hz
Solax Battery Inverter
Parameter
Unit
DC Voltage 1, 2
V
Device Temperature
°C
Charge Capacity
%
BMS Status
—
Frequency
Hz
Solax Power X3 Fourth
42 parameters including full AC measurements and up to 12 DC inputs.
Solax X3-ULTRA Hybrid Primary
41 parameters including PV1–PV3, dual battery packs, and per-phase grid measurements.
SolarEdge
SolarEdge Sunspec 3 Phase Inverter
SunSpec-compliant profile (33 parameters) with scale factors, DC/AC measurements, yield, and status.
SolarEdge Sunspec 3 Phase Inverter v2
Simplified profile (21 parameters) without scale factor registers.
Solis
Solis 3 Phase Inverter
Parameter
Unit
Active power
kW
Yield
kWh
Current L1, L2, L3
A
Grid Frequency
Hz
Inverter status
—
Reactive / Apparent power
kVar / kVA
DC1–DC4 Voltage & Current
V / A
Solis 3 Phase Inverter 10 MPPT
30 parameters with 10 DC inputs and export limit %.
Solis Inverter via EPM
58 parameters with up to 20 DC inputs, fault codes, and cabinet temperature.
Solis Hybrid Inverter
27 parameters including DC inputs, battery voltage/current/SOC/SOH, and grid standards.
SunGrow
SunGrow Inverter SG225-350HX
80 parameters featuring:
- Up to 16 MPPT inputs (Voltage & Current)
- Up to 32 DC string currents
- Full AC measurements
- Export Limit %
- Work Status codes
13 parameters: SOC, SOH, SOE, capacities, charge/discharge power, ESS power adjustment, stable charge/discharge power, total energy.
BESS Rack-Level Devices
Huawei SmartLogger LUNA2000B
Comprehensive rack-level profile (117 parameters):
- SOC, charge/discharge power, capacities
- 52 alarm registers
- Battery cabin temperature/humidity, CO concentration
- Exhaust fan speeds, LTMS status
- Cooling system temperatures
- Rack voltage/current, SOH/SOE/DOD
- Per-pack voltage, SOC, SOH (4 packs)
- AC measurements, working mode
Weiheng AC/FF/C 1 (v1)
24 parameters covering air conditioning, firefighting, and cooler subsystems:
- Temperature, Humidity
- AC states & faults
- Firefighting states & faults
- Cooler temperatures, pressures, states & faults
Weiheng PCS 1 (v1)
41 parameters — full per-phase AC measurements, DC voltage/current, air temperature, power factor, and PCS states/alarms/faults.
Weiheng Cell 1 (v1)
Parameter
Unit
Cell Voltage
V
Cell Temperature
°C
Weiheng EMS (v1)
Comprehensive EMS profile (193 parameters) combining:
- EMS system parameters (max power, system status, grid frequency, energy)
- Firefighting & cooler subsystem data
- Dual PCS with per-phase AC/DC measurements, states & faults
- BMS data with SOC, SOH, cluster-level cell data
- ESS power adjustment & heartbeat control
PLCs & Protection Relays
ABB PLCs
ABB G59 CM-UFD M33M
Parameter
Unit
Frequency
Hz
Trip Count
—
Voltage L1-N, L2-N, L3-N
V
Last Trip Reason
—
ABB G99 CM-UFD M33M
20 parameters: Average and instantaneous voltages (L-N and L-L), Frequency, Last Trip Reason, Trip Count, Status Bits.
Ashbridge
Ashbridge Protection Unit
Parameter
Unit
Winding Temperature 1
°C
Top Oil Temperature 1
°C
Logo PLCs (Siemens)
Logo PLC Generic
8 digital outputs (Output 1–8).
Logo Pulse Counters
Available in 5 scaling variants: 0.01, 0.1, 1, 10, 100 per unit.
2 parameters: Irradiance (W/m²), Module Temperature (°C).
3S-IS Irradiance Only
1 parameter: Irradiance (W/m²).
3S-Albedo
Parameter
Unit
Irradiance 1, 2
W/m²
Temperature Compensated Irradiance 1, 2
°C
Internal Temperature 1, 2
°C
Albedo
—
3S-SMS-MB (Soiling)
Parameter
Unit
Irradiance 1, 2
W/m²
Temperature Compensated Irradiance 1, 2
°C
Internal Temperature 1, 2
°C
Instant Soiling Level
—
Daily Average Soiling Level
—
Instant/Daily Average Soiling Level %
%
Soiling Rate
%
SHT20 Temp & Humidity Sensor
Parameter
Unit
Ambient Temperature
°C
Humidity
%
THT2 I Temp & Humidity Sensor
Parameter
Unit
Ambient Temperature
°C
Humidity
%
Dew Point
°C
TQS4 Temp Sensor
Parameter
Unit
Ambient Temperature
°C
SMA SI4.4M Weather
Parameter
Unit
Horizontal Irradiance
W/m²
SMA Data Logger (Config)
43 parameters containing serial numbers and device IDs for up to 37 connected devices.
RUT2XX (Router/Modem)
Parameter
Unit
RSSI
dBm
String Monitors
Gantner String Bloxx 116-E
Parameter
Unit
dio1, dio2
—
DC Current 1–16
A
DC Current Total
A
DC Voltage
V
DC Power
kW
Temperature
°C
Heat Meters
Sontex Heat Meter
Parameter
Unit
Energy totalizer heating
—
Flow
m³/h
High temperature
°C
Low temperature
°C
This document was auto-generated from the Modbus map definitions. For register-level details (addresses, data types, scaling factors, endianness), refer to the individual JSON map files.
This article was last modified: 11 Jun 2026, 12:50 p.m.